Difference between revisions of "VCLTestToolIssues"
(new issue about timeout) |
m (reformating) |
||
| Line 6: | Line 6: | ||
= 75147 Server Timeout at .exists() = | = 75147 Server Timeout at .exists() = | ||
| − | + | Issue 75147 testtool: respect .exists( time ) value over 'Server Timeout' | |
| − | + | ||
| − | + | Effect: If the value for Server Timeout in the TestTool Settings is lower than the value in the .exist() command, an error comes up, telling you a Server Timeout happened. | |
| − | + | ||
| − | + | This only happens, if the dialog, that is waited for, needs longer to come up, than the value of the Server Timeout is. | |
| − | + | ||
| + | Workaround: The default of the Server Timeout is 45 seconds; | ||
| + | |||
| + | The test runner might change this to 3 minutes or the script writer uses something like this: | ||
<pre> | <pre> | ||
Dim i as integer | Dim i as integer | ||
| Line 21: | Line 24: | ||
= 73372 Crash with URP_Bridge= | = 73372 Crash with URP_Bridge= | ||
| − | + | ||
| − | from SRC680m196 | + | No issue in TestTool, but in OOo with annoying automated testing: from SRC680m196 |
| − | + | ||
| − | + | Issue 73372 Exception not caught: URP_Bridge: disposed | |
| − | + | ||
| − | + | Visible in OOo 2.2 | |
| + | |||
| + | Effect: TestTool and OOo crash - somtimes with messagebox about URP_Bridge. | ||
| + | |||
| + | Workaround: Restart test. | ||
| + | |||
| + | Fixed until OOo 2.3 | ||
= 69840 byRef= | = 69840 byRef= | ||
| − | + | Issue 69840 parameter are no longer passed byRef to sub routines | |
| − | + | ||
| − | + | Effect: Some variables don't change. | |
| − | + | ||
| + | Workaround: Declare each variable in a new line. Or Use last official TestTool SRC680m50 | ||
| + | |||
| + | Not all test scripts are updated yet, to workaround this issue. | ||
= 63620 black snapshots= | = 63620 black snapshots= | ||
| − | + | Issue 63620 testtool: comand snapshot only gets black pictures | |
| − | + | ||
| − | + | Effect: When making automated screenshots, some are black. | |
| − | + | ||
| + | Workaround: none | ||
| + | |||
| + | Currently under evaluation to find a culprint. | ||
[[Category:Quality Assurance]] | [[Category:Quality Assurance]] | ||
Revision as of 11:07, 9 March 2007
draft version
Last official version is SRC680m50 for testing OOo 2.0 - 2.2 Next version will be around SRC680m210 for testing OOo 2.3 - ... (Which might also be used for testing 2.0 - 2.2)
75147 Server Timeout at .exists()
Issue 75147 testtool: respect .exists( time ) value over 'Server Timeout'
Effect: If the value for Server Timeout in the TestTool Settings is lower than the value in the .exist() command, an error comes up, telling you a Server Timeout happened.
This only happens, if the dialog, that is waited for, needs longer to come up, than the value of the Server Timeout is.
Workaround: The default of the Server Timeout is 45 seconds;
The test runner might change this to 3 minutes or the script writer uses something like this:
Dim i as integer
i=0
while (NOT .exists(10) AND i<10)
i = i+1
wend
73372 Crash with URP_Bridge
No issue in TestTool, but in OOo with annoying automated testing: from SRC680m196
Issue 73372 Exception not caught: URP_Bridge: disposed
Visible in OOo 2.2
Effect: TestTool and OOo crash - somtimes with messagebox about URP_Bridge.
Workaround: Restart test.
Fixed until OOo 2.3
69840 byRef
Issue 69840 parameter are no longer passed byRef to sub routines
Effect: Some variables don't change.
Workaround: Declare each variable in a new line. Or Use last official TestTool SRC680m50
Not all test scripts are updated yet, to workaround this issue.
63620 black snapshots
Issue 63620 testtool: comand snapshot only gets black pictures
Effect: When making automated screenshots, some are black.
Workaround: none
Currently under evaluation to find a culprint.